Flat receptacles

Flat receptacles and angled flat receptacles

Blade receptacles are available in insulated or uninsulated design. They can be used in various applications. They are used for connecting cables to loudspeakers, switching voltage and supply voltage connections. The sleeves can also be used as ground strap, protective conductor connection or in the automotive sector. The durable blade receptacles are used in the installation of car radios, car phones and other technical equipment.

Blade receptacles are available in various designs, lengths and widths. The common sizes are 4.8 mm and 6.35 mm. The color of the insulation indicates the workable cable cross-section. The width can be chosen between 0.5 and 0.8 mm. There are uninsulated, partly insulated and fully insulated blade receptacles.

Blade receptacles uninsulated: 2,8 to 6,35 mm, 0,25 to 6,00 mm²
Blade receptacles 6,3 mm partly insulated, 0,25 to 6,00 mm²
Blade receptacles 6,3 mm fully insulated, 0,25 to 6,00 mm²

Assembled cables and lines with blade receptacle in our Cable configurator!

Color-coding:

Cross-section    Insulation color
0,25 to 1,50 mm²    red
1,50 to 2,50 mm²    blue
4,00 to 6,00 mm²    yellow

 

Processing of flat receptacles

Flat receptacles are crimped on with special crimping or pressing pliers. For this purpose, the cable to be fitted with a flat receptacle is stripped to the length specified by the manufacturer. The sleeve matching the conductor cross-section is then placed on the stripped end piece and formed with the crimping pliers or a press with an appropriate die. The deformation creates a secure connection between the stranded wire and the flat ferrule. In order to have a quality control, some crimping pliers leave a marking in the sleeve. The crimping pliers have an engraving in the die for this purpose.

Blade receptacle finished cable assembled


Blade receptacle with branch joint

Flat receptacle with branch

Flat receptacle with branch is suitable for connecting two participants to one flat plug. The flat receptacle with branch is available in different versions, lengths and widths. The common sizes are 4.8 mm and 6.35 mm.

We can supply you with flat receptacle with branch ready assembled with matching wire / cable in the following cross-sections:

uninsulated 4,8x0,8mmuninsulated 4,8x0,8mm0,50mm², 0,75mm², 1,00mm², 1,50mm², 2,50mm²
uninsulated 6,3x0,8mmuninsulated 6,3x0,8mm0,50mm², 0,75mm², 1,00mm², 1,50mm², 2,50mm²
partly insulated 6,3x0,8mmpartly insulated 6,3x0,8mm0,50mm², 0,75mm², 1,00mm², 1,50mm², 2,50mm², 4,00mm², 6,00mm²

Blade receptacle finished cable assembled


Angled blade receptacle

Angled flat receptacles

Angled flat receptacles (like flat receptacles only unwound) are available in different versions, lengths and widths. The common sizes are 4.8 mm and 6.35 mm.

We can supply you with angled flat blade receptacles ready assembled with the appropriate wire / cable in the following cross-sections:

fully insulated 4,8x0,8mmfully insulated 4,8x0,8mm0,50mm², 0,75mm², 1,00mm²
uninsulated 6,3x0,8mmuninsulated 6,3x0,8mm1,00mm², 1,50mm², 2,50mm²